OFTEC Kerosene Oil Combustion Engineering
Oil boilers atomize Class C2 kerosene at 8–12 bar pressure through a precision nozzle, mixing with combustion air for high-efficiency heat transfer.
Precise sizing for kerosene 28-second oil-fired combi, system, and external regular boilers.
OFTEC-matched Danfoss / Delavan oil nozzle size calibrated for clean, soot-free combustion at 93%+ ErP efficiency.
For decades, installers applied a sloppy rule of thumb: Add 30% extra capacity just in case. In modern condensing gas boilers, oversizing causes severe short-cycling, wastes 10–15% of annual fuel, and causes premature component failure.
Ideal is 1 to 2 continuous long modulation burns.
❌ Condensing HALTED (>54°C)
ErP rated at 94% on lab test bench.
Wasted in pre-purge exhaust & lost condensation.
When a boiler is too powerful, it dumps heat into the radiators faster than the rooms can absorb it. The water returns hot within 2 minutes, forcing the burner to shut off, only to refire minutes later. This rapid cycling loses 8–15% in standby ignition losses.
Modern A-rated boilers only achieve 92–94% efficiency when return water stays below 54°C (130°F). An oversized unit forces temperatures above 65°C immediately, preventing latent heat condensation and dropping true efficiency.
Ignition spark generators, gas solenoid valves, circulating pumps, and heat exchanger seams suffer severe thermal stress from 100+ ignitions a day, causing expensive leaks and fan failures within 4 to 6 years.
Kerosene (Class C2 28-second oil) has a net calorific value of 10.3 kWh per Litre. At 93% condensing efficiency, every 1 kW of heat output requires 0.104 Litres of oil per hour.
Standard factory kW brackets, burner nozzle selections, and kerosene consumption rates.
| Oil Output Bracket | Factory Burner Nozzle | Oil Pump Pressure | Fuel Consumption | Optimal Property Type |
|---|---|---|---|---|
| 15 kW – 21 kW | 0.50 – 0.55 USgph 80°EH | 8.0 – 9.0 bar | 1.55 – 2.18 L/hr | 2–3 Bed Rural Cottage / Bungalow |
| 21 kW – 26 kW | 0.60 – 0.65 USgph 80°EH | 8.5 – 10.0 bar | 2.18 – 2.70 L/hr | 3–4 Bed Detached Rural Home |
| 26 kW – 36 kW | 0.75 – 0.85 USgph 80°EH | 9.0 – 11.5 bar | 2.70 – 3.75 L/hr | 4–5 Bed Large Farmhouse |
| 36 kW – 46 kW | 1.00 – 1.10 USgph 60°S | 10.5 – 12.5 bar | 3.75 – 4.80 L/hr | Large Estate / Multi-Zone |
Nozzle spray angles calibrated for high-efficiency multi-pass secondary condensing heat exchangers.
The 2 variables that move the oil boiler result most, and how OFTEC Technical Books & BS 5410 expects each one to be established.
Unlike gas burners that modulate down to 1:10, most pressure-jet oil burners are fixed 1-stage or 2-stage fire.
When the oil storage tank is located below burner level, a Tigerloop de-aerator eliminates air bubbles without a tank return line.
The mistake below costs more than any other on a oil boiler job — nozzle and combustion mismatches that waste fuel and soot the heat exchanger.
Consequence: Severe short-cycling causes soot buildup on baffles.
Put these 2 questions to your heating engineer before you approve a quoted output — each one checks the specification against OFTEC Technical Books & BS 5410.
Oil boilers atomize Class C2 kerosene at 8–12 bar pressure through a precision nozzle, mixing with combustion air for high-efficiency heat transfer.
Formulations benchmarked against OFTEC Technical Books & BS 5410 (Oil Firing Technical Association (OFTEC) & BSI) for Oil Boiler Size Calculator.
2 questions we are asked most about oil boiler sizing, answered against Oil Firing Technical Association (OFTEC) & BSI guidance.
Explore our complete suite of dedicated heating engines, pipe sizing tools, house archetype guides, and brand comparison calculators:
Calculate DHW L/min & GPM flow capacity for instantaneous showers.
Calculate space heating kW + unvented cylinder recovery capacity.
Open-vented gravity systems with loft header tanks.
Cascade systems and plate heat exchangers (50 kW – 500+ kW).
Calculate Boiler Horsepower (BHP) and steam flow in lbs/hr.
High-capacity industrial thermal process and manufacturing loads.
Mains natural gas condensing output with modulation analysis.
Peak gas volume flow and instantaneous hot water demand.
Kerosene 28-second oil-fired combi, system, and external units.
Thermal store oil combination boilers for rural homes.
Kilowatt capacity and single-phase 60A/100A main fuse limits.
Direct electric combination flow rates and amperage requirements.
Bulk tank and 47kg cylinder LPG condensing boiler sizing.
Wood pellet boilers and 50L/kW thermal buffer accumulator tanks.
Batch-fired log gasification boilers and heat accumulators.
Outdoor hydronic wood furnaces for homes and workshops.
Calculate expansion vessel volume in Litres and pre-charge bar.
Calculate copper pipe diameter (15-28mm) for ≤ 1.0 mbar drop.
Flow velocity & diameter (15mm to 35mm) by kW circuit load.
Concentric 60/100mm & 80/125mm equivalent length and bend penalties.
Water volume in Litres and chemical inhibitor bottle dosing.
Firetube & watertube OD, BWG gauge, and thickness lookup table.
Room-by-room Watts & BTU for Type 11, 21, and 22 radiators at ΔT50.
Fabric U-values, air infiltration, and winter design temperature.
Calculate annual fuel wasted from oversized boiler short-cycling.
Compare 70°C gas vs 45°C heat pump radiator surface uprating.
Split heat calculation: output to room vs output to radiators.
24 kW combi sizing for compact flats and terraced properties.
28–30 kW combi or 15–18 kW system boiler recommendations.
High-demand family homes with 2+ bathrooms and en-suites.
Large 24–32 kW system boilers + 300L unvented cylinders.
Square feet / m² heat loss conversion across climate zones.
Low-temperature manifold blending and minimum burner modulation.
Hydronic radiant floor loops and low-temperature condensing.
CIBSE domestic heating design guide and Gas Safe standards.
Irish home heating standards and SEAI energy upgrade guidelines.
Dedicated oil boiler sizing for rural Irish detached homes.
OFTEC standards for kerosene central heating in rural UK.
Severe cold climate sizing (-30°C) in MBH and kW.
Greenstar 2000, 4000, and 8000 series sizing comparison.
ecoTEC pro, plus, and exclusive series kilowatt matching.
Cupboard-fit Baxi 600, 800, and Platinum combi/system sizing.
1:10 Inox-Radial Vitodens 050-W and 100-W efficiency matrix.
Ideal Logic+ and Vogue Max boiler capacity matching.
Glow-worm Energy and Compact combi/system output guide.
Grant Vortex internal and outdoor condensing oil boilers.
Weatherproof external and utility room kerosene oil units.
Independent comparison of British Gas standard & premium tiers.
North American cast iron Sentry, Bobcat, and Intrepid MBH models.